TIERA Book demo ->

JB24T — 24-Channel BNC Junction Box

24 BNC channels, 3 rows × 8, screw-fixed cover — the largest standard bench layout in the family.

SKU: JB24T

Used in
Structural TestingModal AnalysisAcoustic TestingDefence & Aerospace
JB24T — 24-Channel BNC Junction Box
At a glance
  • 24 channels, 3 rows × 8
  • Screw-fixed cover, no hinge — standard T-series build
  • Rubber bench feet
  • BNC female-to-female panel-mount, one per channel
  • ±0.1 dB flatness, 10 Hz–20 kHz
  • 1-year warranty
Specifications
Channels 24
Panel layout 3 rows × 8
Form factor T-series bench, screw-fixed cover
Connector BNC, female-to-female, panel-mount, ×24
Cover Screw-fixed flat top panel, no hinge — screw pattern visible, exact count not recounted
Mounting Rubber bench feet
Cable glands Not visible in this model's source image (side wall not shown) — sized to the cable bundle, confirmed at order engineering
Footprint Largest bench-scale enclosure in the family before the chassis build (indicative — not a measured dimension)
Flatness ±0.1 dB, 10 Hz – 20 kHz
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 1000 MΩ
Warranty 12 months

The JB24T panel carries channels 01–24 across three rows of eight, on the same screw-fixed, flat top panel as every smaller studio-rendered T-series model. Construction is unchanged from JB04T through JB24T: powder-coated black steel, a screw-fixed cover, rubber bench feet, no hinge or lock.

JB24T is the practical ceiling for a single flat, ungrouped panel in this family. Above 24 channels, a panel wide enough to need scanning left-to-right across three or more rows starts to justify grouping channels by structure zone or DAQ card — which is where the chassis-configured build becomes an option, starting at JB48T.

Electrical specification

ParameterValue
Flatness±0.1 dB, 10 Hz – 20 kHz
Contact resistance≤ 5 mΩ
Insulation resistance≥ 1000 MΩ
ConnectorBNC, female-to-female, panel-mount bulkhead

This is a passive assembly with no active device in the signal path. THD and noise-floor figures (≤ 0.001% / ≤ −120 dBV, reported on request) are null-result measurements confirming the assembly adds no detectable distortion or noise above a calibrated analyser’s own floor — not a spec the box “achieves” the way an active instrument would.

Typical applications

  • Larger modal test grids and multi-zone microphone arrays
  • Full-fixture accelerometer sets before a project needs the chassis build
  • Structural health monitoring installations with a moderate point count

See current pricing and configuration options on the TIERA store.


Pairs with:

  • Junction Box family — full line-up, configuration matrix and electrical spec
  • JB48T — next size up, where the chassis build becomes an option
  • PhonoVibe Series — multi-channel DAQ to receive the routed channels
More views
JB24T — 24-Channel BNC Junction Box detail

Want to buy or trial it?

Email Varghese (sales) or book a 20-minute demo call.

Book demo WhatsApp Call