TIERA Book demo ->

JB04T — 4-Channel BNC Junction Box

The smallest box in the family — 4 BNC channels in a single row, screw-fixed cover.

SKU: JB04T

Used in
Structural TestingModal AnalysisAcoustic TestingDefence & Aerospace
JB04T — 4-Channel BNC Junction Box
At a glance
  • 4 channels, single row — the whole panel is readable at a glance
  • Screw-fixed cover, no hinge — standard T-series build
  • Rubber bench feet
  • BNC female-to-female panel-mount, one per channel
  • ±0.1 dB flatness, 10 Hz–20 kHz
  • 1-year warranty
Specifications
Channels 4
Panel layout 1 row × 4
Form factor T-series bench, screw-fixed cover
Connector BNC, female-to-female, panel-mount, ×4
Cover Screw-fixed flat top panel, ~8 screws (corners + edge-midpoints), no hinge
Mounting Rubber bench feet
Cable glands Not visible in this model's source image (side wall not shown) — sized to the cable bundle, confirmed at order engineering
Footprint Compact desktop enclosure, single-hand liftable (indicative — not a measured dimension)
Flatness ±0.1 dB, 10 Hz – 20 kHz
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 1000 MΩ
Warranty 12 months

The JB04T panel carries channels 01–04 in a single row, with the TIERA logo top-left and the model code and serial number (S/N JB04T26001) top-right — the same legend convention used across the whole family. The cover is screw-fixed on a flat top panel, held by roughly 8 screws at the corners and edge-midpoints, with no hinge and no lock.

At 4 channels, a single flat row is enough — there is no case for zoning at this size, and none is offered. The box shares the family’s electrical specification unchanged: what varies model to model in this family is channel count and panel layout, not measurement performance.

Electrical specification

ParameterValue
Flatness±0.1 dB, 10 Hz – 20 kHz
Contact resistance≤ 5 mΩ
Insulation resistance≥ 1000 MΩ
ConnectorBNC, female-to-female, panel-mount bulkhead

This is a passive assembly with no active device in the signal path. THD and noise-floor figures (≤ 0.001% / ≤ −120 dBV, reported on request) are null-result measurements confirming the assembly adds no detectable distortion or noise above a calibrated analyser’s own floor — not a spec the box “achieves” the way an active instrument would.

Typical applications

  • Small fixed-point accelerometer sets on a test fixture
  • A reference or trigger channel alongside a larger sensor array
  • Bench setups where 4 channels is the whole requirement

See current pricing and configuration options on the TIERA store.


Pairs with:

More views
JB04T — 4-Channel BNC Junction Box detail

Want to buy or trial it?

Email Varghese (sales) or book a 20-minute demo call.

Book demo WhatsApp Call