TIERA Book demo ->

JB16T — 16-Channel BNC Junction Box

16 BNC channels, 2 rows × 8, screw-fixed cover — matched to a 16-channel DAQ.

SKU: JB16T

Used in
Structural TestingModal AnalysisAcoustic TestingDefence & Aerospace
JB16T — 16-Channel BNC Junction Box
At a glance
  • 16 channels, 2 rows × 8
  • Screw-fixed cover, no hinge — standard T-series build
  • Rubber bench feet
  • BNC female-to-female panel-mount, one per channel
  • ±0.1 dB flatness, 10 Hz–20 kHz
  • 1-year warranty
Specifications
Channels 16
Panel layout 2 rows × 8
Form factor T-series bench, screw-fixed cover
Connector BNC, female-to-female, panel-mount, ×16
Cover Screw-fixed flat top panel, no hinge — screw pattern visible, exact count not recounted
Mounting Rubber bench feet
Cable glands Not visible in this model's source image (side wall not shown) — sized to the cable bundle, confirmed at order engineering
Footprint Bench enclosure (indicative — not a measured dimension)
Flatness ±0.1 dB, 10 Hz – 20 kHz
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 1000 MΩ
Warranty 12 months

The JB16T panel carries channels 01–16 across two rows of eight, on the same screw-fixed, flat top panel as the rest of the studio-rendered T-series models. The legend and construction match every other bench model in the family: TIERA logo top-left, model code and serial top-right, 16 CHANNEL JUNCTION BOX along the lower edge.

Sixteen channels is a common acquisition-system size — this model pairs naturally with a single 16-channel DAQ, keeping the sensor-to-input mapping one-to-one without splitting an array across two boxes.

Electrical specification

ParameterValue
Flatness±0.1 dB, 10 Hz – 20 kHz
Contact resistance≤ 5 mΩ
Insulation resistance≥ 1000 MΩ
ConnectorBNC, female-to-female, panel-mount bulkhead

This is a passive assembly with no active device in the signal path. THD and noise-floor figures (≤ 0.001% / ≤ −120 dBV, reported on request) are null-result measurements confirming the assembly adds no detectable distortion or noise above a calibrated analyser’s own floor — not a spec the box “achieves” the way an active instrument would.

Typical applications

  • Setups built around a 16-channel DAQ
  • Modal test grids and microphone arrays in the 16-channel range
  • Structural health monitoring point sets

See current pricing and configuration options on the TIERA store.


Pairs with:

More views
JB16T — 16-Channel BNC Junction Box detail

Want to buy or trial it?

Email Varghese (sales) or book a 20-minute demo call.

Book demo WhatsApp Call